Sets the outflow parameters used in the lake water balance. Outflow is calculated at each timestep as:
Arguments
- aeme
Aeme object.
- C
numeric; outflow coefficient. Scales the magnitude of outflow when water level exceeds
h_inv.- h_inv
numeric; inversion height (m). The water level threshold below which outflow is zero.
- params
Optional named numeric vector with elements
"C"and"h_inv", as returned byget_wbal_paramfor a single model. If supplied, overrides the individualCandh_invarguments. Alternatively, a family-keyed list as returned byget_wbal_paramwith nomodel– each entry is applied directly to its own family, andmodelis ignored.- model
character; model name(s) to set parameters for (e.g.
"glm_aed"). IfNULL(default), the same values are applied to every evaporation family (dy_cd/glm_aed,gotm_wet,simstrat_aed2). Ignored ifparamsis a family-keyed list.
Details
$$O_t = C \cdot \max(h_t - h_{inv}, 0)^{1.5} \times 86400$$
where \(O_t\) is outflow (m\(^3\)/day), \(h_t\) is the simulated water level (m), \(h_{inv}\) is the inversion height (m), \(C\) is the outflow coefficient, and 86400 converts seconds to days.
Parameters are stored per evaporation family, since dy_cd/glm_aed
share one fitted set and gotm_wet/simstrat_aed2 each have their own
(see calc_water_balance). Use model to set a
specific model's parameters; omit it to apply the same values to every
family (matching the pre-per-family behaviour).